T Type Burner

These high pressure burners are recommended for heating curved surface vessels as they produce powerful torch type flames. O Working pressure should not be varied by more than +0.07 kgf/cm2 (+1 psig). Use of these burners at pressure higher than 0.42 kgf/cm2 (6 psis) will result in sastage of gas. At a pressure of 20 psig. the gas consumption per hour will be double. O The nomenclature T-22 of T-35 is derived from the gas consumption rate which is 2.2 lb/hr for T-22 and 3.5 lb/hr for T-35, while T symbolizes torch. O The burner rated heat outputs are valid for altitudes upto 2000 ft above sea level. If altitude is more than 2000 ft, rated heat outputs should be reduced @4% per extra 1000 ft altitude.